Analisa Koordinasi Relay Proteksi OCR dan Recloser Pada Sistem Distribusi 20kV

Agung Prastyo, Trisna Wati

Abstract


Based on data from the PT PLN Bojonegoro main substation, there were 3 disruptions a month, which caused several distribution feeders to trip. One of the causes of a trip in this protection system is due to an error in the coordination settings between the Over Current Relay (OCR) and the recloser. The aim of this research is to review the value of the OCR and recloser settings on the 20 kV distribution channel at the Bojonegoro Main Substation to maximize how the protection equipment works in the event of a disturbance. The calculation results for the recloser are 0.07 seconds, the incoming OCR is 0.27 seconds, and the outgoing OCR is 0.11 seconds. Meanwhile, the existing TMS OCR and recloser values are 0.1 seconds, the incoming OCR is 0.25 and the outgoing OCR is 0.2 seconds. . Comparison of the TMS OCR incoming, OCR Outgoing, and recloser value settings has a difference of 0.03 seconds, 0.0.02 seconds, and 0.09 seconds.


Full Text:

PDF

References


Beth M, “Analisa Koordinasi Over Current Relay Dan Recloser Pada Penyulang Distribusi 20 KV Di Gardu Induk Jajar,” Thesis, Universitas Muhammdiyah Surakarta, Surakarta, 2022.

R. Andriyan, R. Adzin Murdiantoro, “Analisis Koordinasi Over Current Relay (OCR) Dan Ground Fault Relay (GFR) Pada Sistem Distribusi 20 KV Studi Kasus di PT. PLN (Persero) ULP Sidareja,” JEEPA, pp. 1–7, 2022.

A. Yossi, W Trisna “Analisa Relay Jarak Pada Saluran Transmisi 150KV Gardu Induk,” SNESTIK , vol. 1, no. 2775–5126, pp. 1–7, Jun. 2021.

I. Bakara, I. Baskara, I. W. Sukerayasa, and W. G. Ariastina, “Studi koordinasi peralatan proteks OCR DAN GFR pada Penyulang Tibubeneng,” Teknologi Elektro, vol. 14, no. 2, pp. 1–7, 2018.

M. Imran and A. Bintoro, “Analisa keandalan sistem distribusi tenaga listrik untuk wilayah kota Lhokseumawe di PT. PLN (PERSERO) Rayon Kota Lhokseumawe,” Energi Elektrik, vol. 8, no. 1, pp. 1–6, 2019. Seminar Nasional Teknik Elektro, Sistem Informasi, dan Teknik Informatika ISSN 2775-5126 FTETI - Institut Teknologi Adhi Tama Surabaya.

Arifin Muchammad, “Analisi koordinasi sistem proteksi Over Current Relay dan Recloser pada penyulang MJO5 DI PT PLN UP3 Klaten menggunakan aplikasi ETAP 12.6.0,” Thesis, Universitas Muhammadiyah Surakarta, Surakarta, 2022.

Saputra FA, “Analisis setting Over Current Relay (OCR) Ground Fault Relay (GFR) DAN Recloser feeder di PT. PLN (PERSERO) Rajapolah dengan aplikasi ETAP 16.0.0,” Universitas Siliwangi, Tasikmalaya, 2022.

I Wayan Sukadana and Risma Fauziyah Ramadhani, “Koordinasi Proteksi Arus Lebih Penyulang Tembuku terhadap Indeks Keandalan Sistem Distribusi 20 KV PT. PLN (Persero) ULP Bangli,” J-Eltrik, vol. 2, no. 2, p. 104, Nov. 2021, doi: 10.30649/jeltrik.v2i2.104.

W. Wijana, I. Ketut Wijaya, and I. M. Mataram, “Analisis koordinasi relay arus lebih (OCR) dan Recloser pada sistem eksisting Penyulang Bukit Jati,” SPEKTRUM , vol. 5, no.2, pp. 1–6, 2018.

W. P. Perdana, “Evaluasi Keandalan Sistem Tenaga Listrik Pada Jaringan Distribusi Primier Tipe Radial Gardu Induk Blimbing,” ECCIS, vol. III, Jun. 2019.

I. D. G. Agung, B. Udiana, I. G. Dyana Arjana, T. Gede, and I. Partha, “Studi Analisis Koordinasi Over Current Relay (OCR) dan Ground Fault Relay (GFR) pada Recloser di Saluran Penyulang Penebel,” Teknologi Elektro, vol. 16, no. 02, pp. 1–6, 2017.

Mahsur Irham, “Analisis gangguan SUTM Dan dampak terhadap energi tidak tersalur pada Penyulang Pasar Karisa PT PLN ULP Jeneponto,” Tesis, Universitas Muhammdiyah Makassar, Makassar, 2021.

Adi Lukmanul Khakim, “Analisa kedip tegangan saluran distribusi 20 kV akibat hubung singkat asimetris menggunakan metode thevenin di Gardu Induk PT PLN Bojonegoro,” Thesis, Institut Teknologi Adhi Tama Surabaya, Surabaya, 2020.




DOI: https://doi.org/10.31284/p.snestik.2024.5545

Refbacks

  • There are currently no refbacks.


Copyright (c) 2024 Agung Prastyo

Creative Commons License
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.